CLI Commands: Base
CLI L2P
Release
7.0
05/2011
4.7
Syslog Commands
161
4.7.4 logging console
This command enables logging to the console. The <severitylevel> value is
specified as either an integer from 0 to 7 or symbolically through one of the
following keywords: emergency (0), alert (1), critical (2), error (3), warning
(4), notice (5), informational (6), debug (7).
Default
disabled; alert
Format
logging console [severitylevel] | <[0-7]>
Mode
Global Config
severitylevel | [0-7]
Enter Logging Severity Level (emergency|0, alert|1, critical|2, error|3,
warning|4, notice|5, info|6, debug|7).
Note: selecting a lower severity level (larger number) will include all
messages from higher severity levels (smaller numbers).
Possible severity levels: see Table 15
U no logging console
This command disables logging to the console.
Format
no logging console

Table of Contents

Other manuals for Hirschmann RS20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann RS20 and is the answer not in the manual?

Hirschmann RS20 Specifications

General IconGeneral
MountingDIN Rail
Operating Temperature-40°C to +70°C
Protection ClassIP30
Switching TechnologyStore-and-Forward
Product TypeIndustrial Ethernet Switch
Port Details10/100 Mbps Ethernet ports
Switching Capacity3.2 Gbps
MAC Address Table8k
ManagementWeb, SNMP
RedundancyMRP
Ports8 or 16

Related product manuals