4.11
System Utilities
CLI L2P
Release
7.0
05/2011
4.11.23ping
This command checks if another computer is on the network and listens for
connections. To use this command, configure the switch for network (in-
band) connection. The source and target devices must have the ping utility
enabled and running on top of TCP/IP. The switch can be pinged from any IP
workstation with which the switch is connected through the default VLAN
(VLAN 1), as long as there is a physical path between the switch and the
workstation. The terminal interface sends, three pings to the target station.
Format
ping <ipaddr>
Mode
Privileged EXEC and User EXEC
4.11.24signal-contact connection-error
This command configures the signal contact link error monitoring for this port.
Format
signal-contact connection-error {disable|enable}
Mode
Interface Config
disable
A link down event on this port will be not monitored by a signal con-
tact (default).
enable
A link down event on this port will be monitored by a signal contact.

Table of Contents

Other manuals for Hirschmann RS20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann RS20 and is the answer not in the manual?

Hirschmann RS20 Specifications

General IconGeneral
MountingDIN Rail
Operating Temperature-40°C to +70°C
Protection ClassIP30
Switching TechnologyStore-and-Forward
Product TypeIndustrial Ethernet Switch
Port Details10/100 Mbps Ethernet ports
Switching Capacity3.2 Gbps
MAC Address Table8k
ManagementWeb, SNMP
RedundancyMRP
Ports8 or 16