208
4.9
Device Configuration Commands
CLI L2P
Release
7.0
05/2011
4.9.46 set igmp lookup-interval-unknown
This command configures the IGMP Snooping lookup response time for
unknown multicast frames (unit: seconds, min.: 2, max.: 3,599, default: 125).
Format
set igmp lookup-interval-unknown <2-3599>
Mode
Global Config
<2-3599>
Enter the IGMP Snooping lookup response time for unknown multi-
cast frames (unit: seconds, min.: 2, max.: 3,599, default: 125).
4.9.47 set igmp lookup-resp-time-unknown
This command configures the IGMP Snooping lookup interval for unknown
multicast frames (unit: seconds, min.: 1, max.: 3,598, default: 10).
Format
set igmp lookup-resp-time-unknown <1-3598>
Mode
Global Config
<2-3598>
Enter the IGMP Snooping lookup interval for unknown multicast
frames (unit: seconds, min.: 1, max.: 3,598, default: 10).