4.13.13sntp client disable-after-sync
If this option is activated, the SNTP client disables itself once it is synchro-
nised to a server.
Format
sntp client disable-after-sync <on | off>
Mode
Global Config
off
Do not disable SNTP client when it is synchronised to a time server.
on
Disable SNTP client as soon as it is synchronised to a time server.
4.13.14sntp client offset
The offset between UTC and local time in minutes, default: 60.
Format
sntp client offset <-1000 to 1000>
Mode
Global Config

Table of Contents

Other manuals for Hirschmann RS20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann RS20 and is the answer not in the manual?

Hirschmann RS20 Specifications

General IconGeneral
MountingDIN Rail
Operating Temperature-40°C to +70°C
Protection ClassIP30
Switching TechnologyStore-and-Forward
Product TypeIndustrial Ethernet Switch
Port Details10/100 Mbps Ethernet ports
Switching Capacity3.2 Gbps
MAC Address Table8k
ManagementWeb, SNMP
RedundancyMRP
Ports8 or 16