EasyManuals Logo

Hirschmann RS20 Reference Manual

Hirschmann RS20
572 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #302 background imageLoading...
Page #302 background image
302
4.11
System Utilities
CLI L2P
Release
7.0
05/2011
<seconds>
The number of seconds after which the switch will reboot.
Value range: None (no reboot sceduled), 0 - 2,147,483 sec (= 596 h +
31 min + 23 sec) .
4.11.29reload
This command enables you to reset the switch (warm start) after a given time
delay, for cold start See “reboot” on page 301.
Note: First, the device is checking the software in the flash memory and then
it resets. If a warm start is not possible, the device automatically executes a
cold start.
Reset means that all network connections are terminated and the boot code
executes. The switch uses the stored configuration to initialize the switch.
You are prompted to confirm that the reset should proceed. A successful
reset is indicated by the LEDs on the switch.
Format
reload {delay <seconds>}
Mode
Privileged EXEC
<seconds>
The number of seconds after which the switch will reload.
Value range: 0 - 2,147,483 sec.
U clear reload
This command cancels a scheduled reload.

Table of Contents

Other manuals for Hirschmann RS20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann RS20 and is the answer not in the manual?

Hirschmann RS20 Specifications

General IconGeneral
MountingDIN Rail
Operating Temperature-40°C to +70°C
Protection ClassIP30
Switching TechnologyStore-and-Forward
Product TypeIndustrial Ethernet Switch
Port Details10/100 Mbps Ethernet ports
Switching Capacity3.2 Gbps
MAC Address Table8k
ManagementWeb, SNMP
RedundancyMRP
Ports8 or 16

Related product manuals