Page #358 background image
358
4.14
PTP - Precision Time Protocol
CLI L2P
Release
7.0
05/2011
4.14.10ptp v1 preferred-master
Configure the PTPv1 (IEEE1588-2002) specific settings.
Specify if the local switch shall be regarded as a preferred master clock (i. e.,
if it will remain master in the presence of disconnection or connection of other
clocks).
Format
ptp v1 preferred-master {true|false}
Mode
Global Config
true
The local switch shall be regarded as a preferred master clock.
false
The local switch shall not be regarded as a preferred master clock.
4.14.11ptp v1 re-initialize
Configure the PTPv1 (IEEE1588-2002) specific settings.
Re-initialize the clocks in the local subdomain with the currently configured
settings. Changes in the subdomain name or the sync interval will only take
effect after this command.
Format
ptp v1 re-initialize
Mode
Global Config

Table of Contents

Other manuals for Hirschmann RS20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann RS20 and is the answer not in the manual?

Hirschmann RS20 Specifications

General IconGeneral
MountingDIN Rail
Operating Temperature-40°C to +70°C
Protection ClassIP30
Switching TechnologyStore-and-Forward
Product TypeIndustrial Ethernet Switch
Port Details10/100 Mbps Ethernet ports
Switching Capacity3.2 Gbps
MAC Address Table8k
ManagementWeb, SNMP
RedundancyMRP
Ports8 or 16