CLI Commands: Switching
454
5.5
Redundant Coupling
CLI L2P
Release
7.0
05/2011
5.5.1 show ring-coupling
This command displays the settings and states of the network coupling / ring
coupling.
To set up a new Ring Coupling configuration when no configuration is cur-
rently present (e. g., after a clear command), always set the local port first.
Please refer to: ring-coupling port local <slot/port>.
The following details are displayed on execution of the command.
Format
show ring-coupling <config | info |
net-coupling | operation | partner-ip |
port [ all | control | local | partner] |
redundancy-mode>
Mode
Privileged EXEC and User EXEC
config
Display the Ring Coupling's configuration
– single
– dual-master-inband
– dual-master-outband
– dual-slave-inband
– dual-slave-outband.
info
Display information about the Ring Coupling's states:
– configuration failure,
– Extended diagnosis,
– redundancy guaranteed.
net-coupling
Display the Ring Coupling's ring/network coupling setting (network/
ring-only).
operation
Display the Ring Coupling's operation setting
– on
– off

Table of Contents

Other manuals for Hirschmann RS20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann RS20 and is the answer not in the manual?

Hirschmann RS20 Specifications

General IconGeneral
BrandHirschmann
ModelRS20
CategorySwitch
LanguageEnglish

Related product manuals