CLI L2P
Release
7.0
05/2011
4.9
Device Configuration Commands
189
4.9.23 rmon-alarm modify mib-variable
This command modifies the mib-variable of an RMON alarm.
Format
rmon-alarm modify <index> mib-variable <mib-variable>
Mode
Global Config
index
Enter the index of the RMON alarm.
mib-variable
Enter the MIB variable.
4.9.24 rmon-alarm modify thresholds
This command modifies the thresholds of an RMON alarm.
Format
rmon-alarm modify <index> thresholds
<rising-threshold>
<falling-threshold>
Mode
Global Config
index
Enter the index of the RMON alarm.
rising-threshold
Enter the rising threshold for the RMON alarm.
falling-threshold
Enter the falling threshold for the RMON alarm.