299
4.11.25signal-contact
This command configures the signal contacts.
Format
signal-contact {1|2|all}
{mode {auto|device-status|manual}
|monitor {aca-removal|
all|
connection-error|hiper-ring|module-removal
|power-supply-1| power-supply-2
|power-supply-3-1|power-supply-3-2
|power-supply-4-1|power-supply-4-2
|ring-coupling|temperature} {disable|enable}
|state {closed|open}
|trap {disable|enable} }
Mode
Global Config
Contact No.
Selection of the signal contact:
1 signal contact 1,
2 signal contact 2,
all signal contact 1 and signal contact 2.
mode
Selection of the operational mode:
auto function monitoring,
device-status the device-status determines the signal contact´s
status.
manual manually setting the signal contact.
monitor
Enables or disables the monitoring of the selected event or all events.
enable monitoring,
disable no monitoring.
state
Set the manual setting of the signal contact:
closed ,
open.
Only takes immediate effect in manual mode.