4.15.4 inlinepower (Interface Config)
Configure the portrelated Inline Power parameters.
Note: The interface name you enter in the name-command.
Format
inlinepower {admin-mode {disable|enable} |
priority {critical|high|low} }
Mode
Interface Config
admin-mode
Configure the port-related Inline Power administrative setting (enable
or disable, default: enable).
priority
Configure the Inline Power priority for this port. In case of power scar-
city, inline power on ports configured with the lowest priority is
dropped first. Possible values are: critical, high or low, default: low.
The highest priority is critical.
This parameter is available for MACH 1000, MACH 4000 and devices
which support Power over Ethernet Plus (MACH104-16TX-PoEP
devices and MACH 102 devices with media module M1-8TP-RJ45
PoE).
4.15.5 clear inlinepower
Reset the Inline Power parameters to default settings.
Format
clear inlinepower
Mode
Privileged EXEC

Table of Contents

Other manuals for Hirschmann RS20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann RS20 and is the answer not in the manual?

Hirschmann RS20 Specifications

General IconGeneral
MountingDIN Rail
Operating Temperature-40°C to +70°C
Protection ClassIP30
Switching TechnologyStore-and-Forward
Product TypeIndustrial Ethernet Switch
Port Details10/100 Mbps Ethernet ports
Switching Capacity3.2 Gbps
MAC Address Table8k
ManagementWeb, SNMP
RedundancyMRP
Ports8 or 16

Related product manuals