EasyManuals Logo

Hirschmann RS20 Reference Manual

Hirschmann RS20
572 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #213 background imageLoading...
Page #213 background image
CLI L2P
Release
7.0
05/2011
4.9
Device Configuration Commands
213
4.9.54 selftest ramtest
Enable or disable the RAM test for a cold start of the device.
Deactivating the RAM test reduces the booting time for a cold start of the de-
vice.
Default: enabled.
Format
selftest ramtest {disable|enable}
Mode
Global Config
selftest ramtest disable
Disable the ramtest.
selftest ramtest enable
Enable the ramtest. This is the default.
4.9.55 selftest reboot-on-error
Enable or disable a restart due to an undefined software or hardware state.
Default: disabled.
Format
selftest reboot-on-error {disable|enable}
Mode
Global Config
selftest reboot-on-error disable
Disable the reboot-on-error function. This is the default.
selftest reboot-on-error enable
Enable the reboot-on-error function.

Table of Contents

Other manuals for Hirschmann RS20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann RS20 and is the answer not in the manual?

Hirschmann RS20 Specifications

General IconGeneral
MountingDIN Rail
Operating Temperature-40°C to +70°C
Protection ClassIP30
Switching TechnologyStore-and-Forward
Product TypeIndustrial Ethernet Switch
Port Details10/100 Mbps Ethernet ports
Switching Capacity3.2 Gbps
MAC Address Table8k
ManagementWeb, SNMP
RedundancyMRP
Ports8 or 16