Issue 4.0
SV9100 Programming Manual 2-11
For PRTA PKG Setup
19
Numbering Plan Identification
ISDN Protocol definition
0 = Unknown
1 = ISDN numbering plan
2 = Data numbering plan
3 = Telex numbering plan
4 = National standard numbering plan
5 = Private numbering plan
1
23
Straight/Cross Wiring
0 = Auto
1 = Manual (Cross)
2 = Manual (Straight)
0
24
--- Not Used ---
25
Layer 1 Supervision
When set to 0, Layer 1 deactivation is
not considered to be a fault, so the
channel can be usable and alarm #10
not issued. When set to 1, Layer 1
deactivation is considered to be a fault,
so the channel will be skipped and
alarm #10 issued.
0 = Disable
1 = Enable
0
Input Data
ISDN Line Number 01~24
Item
No.
Item Input Data Default
01
ISDN Line Mode
0 = Not Used
1 = T-Point
2 = S-Point (Not used)
3 = NW Mode (Leased Line)
4 = NW Mode (Interconnected Line)
5 = NW Mode (Interconnected Line,
Fixed Layer1 = NT)
6 = S-Point (Leased Line) (Not used)
1
02
Logical Port Number
The start port number of a
PRI line is displayed.
0 = Not used
1 = T-Point (1~400)
2 = S-Point (1~960) (Not used)
3 = NW Mode (Leased Line) (1~256)
4 = NW Mode (Interconnected Line)
(1~256)
5 = NW Mode (Interconnected Line,
Fixed Layer1 = NT) (1~256)
6 = S-Point (Leased Line) (Not used)