WM-Drain setup 16 Water Management setup
Setting Explanation
Engage:Logs data only if Auto is engaged on the plow.
Filter Type
None:Raw GPS data is used for height. This setting is
recommended.
Average:The height will be averaged using the number of
positions selected. This will smooth spikes in height readings
but will introduce a latency into the controls.
Jump detect:This will filter out some jumps in the height
readings. When you select this, you must enter the following
values:
l Threshold:The change in height value that will trigger the
value.
l Decay Time:When this filter is triggered, this will be the
amount of time it takes to gradually resume using the raw
GPSheight.
316 FM-1000 Integrated Display User Guide Version 9.25, Revision B