EasyManuals Logo
Home>Xerox>All in One Printer>VersaLink B7030

Xerox VersaLink B7030 Service Manual

Xerox VersaLink B7030
1341 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #466 background imageLoading...
Page #466 background image
April 2017
2-446
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
041-388, 041-391, 041-603, 041-604
Launch Issue
Status Indicator RAPs
041-388, 041-391 Logic Fail RAP
041-388 When fatal abnormality was detected in marking control.
041-391 Finisher module fatal error was detected.
Procedure
Perform the steps that follow:
1. Switch off, then switch on the machine, GP 10.
2. Reload the software, GP 4.
041-603, 041-604 Environment Sensors Fail RAP
041-603 The value of the temperature sensor exceeds the upper limit.
041-604 The value of the humidity sensor exceeds the upper limit.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1. Switch off, then switch on the machine, GP 10.
2. Ensure that the fusing unit exhaust fan and the marking unit fan are operating correctly,
refer to:
• 042-330 Fuser Exhaust Fan Fail RAP.
• 043-344 Marking Fan Fail RAP.
3. If the fault persists, install a new ESS PWB, PL 3.10 Item 6.
NOTE: The temperature sensor and humidity sensor are both surface mounted on the
ESS PWB.

Table of Contents

Other manuals for Xerox VersaLink B7030

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xerox VersaLink B7030 and is the answer not in the manual?

Xerox VersaLink B7030 Specifications

General IconGeneral
BrandXerox
ModelVersaLink B7030
CategoryAll in One Printer
LanguageEnglish

Related product manuals