ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-107
Settings
1~50Hz: Low stiffness, low response
51~250Hz: Medium stiffness, medium response
251~850Hz: High stiffness, high response
851~1000Hz: Extremely high stiffness, extremely high response
NOTE
1According to the speed loop setting of P2-31, the servo drive sets
the position loop response automatically.
2The function is enabled via parameter P2-32. Please refer to
Chapter 5.6 for corresponding bandwidth size of the setting value.
P2-32
AUT2 Tuning Mode Selection
Address: 0240H
0241H
Operational
Interface
Panel / Software Communication
Related Section:
5.6 and 6.3.6
Default
0
Control
Mode
ALL
Unit
-
Range
0 ~ 0x2
Data Size
16-bit
Format
Hexadecimal
Settings
0: Manual Mode
1: Auto Mode (continuous adjustment)
2: Semi-auto Mode (non- continuous adjustment)

Table of Contents

Other manuals for Delta ASDA-A2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 and is the answer not in the manual?

Delta ASDA-A2 Specifications

General IconGeneral
Control ModePosition, Speed, Torque
ModelASDA-A2 Series
Operating Voltage200 ~ 230VAC / 380 ~ 480VAC
Power Supply200-230VAC ±10%, single-phase
Communication InterfaceRS-485, CANopen
FeedbackIncremental encoder, Absolute encoder
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Operating Temperature0°C
Storage Temperature-20°C
Humidity20% to 90% RH (non-condensing)
Position Control Mode FeaturesElectronic Cam
WeightVaries depending on the model. Please refer to the specific model's datasheet.