Chapter 8 Parameters ASDA-A2
8-36 Revision February, 2017
Bit 0: Absolute position status
0: Normal
1: Absolute position is lost
Bit 1: Voltage level of battery
0: Normal
1: Low battery
Bit 2: Status of encoder multiturn
0: Normal
1: Overflow
Bit 3: Status of PUU
0: Normal
1: Overflow
Bit 4: Absolute coordinate system status
0: Normal
1: Absolute coordinate system has not been set
Bit 5 ~ Bit 15: Reserved. Must be set to 0.
P0-51
APR Encoder Absolute Position (Multiturn)
Address: 0066H
0067H
Operational
Interface
Panel / Software Communication
Related Section: N/A
Default
0x0
Control
Mode
ALL
Unit
rev
Range
-32768 ~ +32767
Data Size
32-bit
Format
Decimal
Settings While the Bit 1 of P2-70 is set to 1 to read the encoder pulse number,
this parameter represents the turns of encoder absolute position. While
the Bit 1 of P2-70 is set to 0 to read the PUU number, this parameter
becomes disabled and the setting value of this parameter is 0.

Table of Contents

Other manuals for Delta ASDA-A2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 and is the answer not in the manual?

Delta ASDA-A2 Specifications

General IconGeneral
Control ModePosition, Speed, Torque
ModelASDA-A2 Series
Operating Voltage200 ~ 230VAC / 380 ~ 480VAC
Power Supply200-230VAC ±10%, single-phase
Communication InterfaceRS-485, CANopen
FeedbackIncremental encoder, Absolute encoder
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Operating Temperature0°C
Storage Temperature-20°C
Humidity20% to 90% RH (non-condensing)
Position Control Mode FeaturesElectronic Cam
WeightVaries depending on the model. Please refer to the specific model's datasheet.

Related product manuals