ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-49
P1-08 PFLT
Smooth Constant of Position Command (Low-
pass Filter)
Address: 0110H
0111H
Operational
Interface
Panel / Software Communication
Related Section:
6.2.6
Default
0
Control
Mode
PTPR
Unit
10 ms
Range
0 ~ 1000
Data Size
16-bit
Format
Decimal
Example
11 = 110 ms
Settings
0: Disabled
P1-09 SP1
Internal Speed Command 1Internal Speed
Limit 1
Address: 0112H
0113H
Operational
Interface
Panel / Software Communication
Related Section:
6.3.1
Default
1000
Control
Mode
ST
Unit
0.1rpm
Range
-60000 ~ +60000
Data Size
32-bit
Format
Decimal
Example
Internal speed command:
120 = 12 r/min
Internal Speed Limit: Positive value and
negative value is the same. Please refer to
the following description.

Table of Contents

Other manuals for Delta ASDA-A2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 and is the answer not in the manual?

Delta ASDA-A2 Specifications

General IconGeneral
Control ModePosition, Speed, Torque
ModelASDA-A2 Series
Operating Voltage200 ~ 230VAC / 380 ~ 480VAC
Power Supply200-230VAC ±10%, single-phase
Communication InterfaceRS-485, CANopen
FeedbackIncremental encoder, Absolute encoder
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Operating Temperature0°C
Storage Temperature-20°C
Humidity20% to 90% RH (non-condensing)
Position Control Mode FeaturesElectronic Cam
WeightVaries depending on the model. Please refer to the specific model's datasheet.

Related product manuals