Chapter 8 Parameters ASDA-A2
8-38 Revision February, 2017
to set the filter timing for the monitoring variable. The value of
monitoring variable will output after the filtering time determined by
parameter P0-53.
For example: when P0-09 is used
P0-54 ZON1L
General Range Compare Digital Output –
Lower Limit of 1st Monitoring Variable
Address: 006CH
006DH
Operational
Interface
Panel / Software Communication
Related Section: N/A
Default
0
Control
Mode
ALL
Unit
-
Range
-2147483648 ~ +2147483647
Data Size
32-bit
Format
Decimal
SettingsThe value of parameter P0-09 will change within the range between P0-
54 and P0-55 and then output after the filtering time determined by
parameter P0-53.
P0-55 ZON1H
General Range Compare Digital Output –
Upper Limit of 1st Monitoring Variable
Address: 006EH
006FH
Operational
Interface
Panel / Software Communication
Related Section: N/A
Default
0
Control
Mode
ALL
Unit
-
Range
-2147483648 ~ +2147483647
Data Size
32-bit

Table of Contents

Other manuals for Delta ASDA-A2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 and is the answer not in the manual?

Delta ASDA-A2 Specifications

General IconGeneral
Control ModePosition, Speed, Torque
ModelASDA-A2 Series
Operating Voltage200 ~ 230VAC / 380 ~ 480VAC
Power Supply200-230VAC ±10%, single-phase
Communication InterfaceRS-485, CANopen
FeedbackIncremental encoder, Absolute encoder
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Operating Temperature0°C
Storage Temperature-20°C
Humidity20% to 90% RH (non-condensing)
Position Control Mode FeaturesElectronic Cam
WeightVaries depending on the model. Please refer to the specific model's datasheet.

Related product manuals