ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-173
P5-26 AC6 Acceleration/Deceleration Time (Number #6)
Address: 0534H
0535H
Operational
Interface:
Panel / Software Communication
Related Section:
7.10
Default:
1000
Control
Mode:
PR
Unit:
ms
Range:
1 ~ 65500
Data Size:
16-bit
Format:
Decimal
Settings:
Please refer to P5-20 for the setting of acceleration/deceleration time in
PR mode.
P5-27 AC7 Acceleration/Deceleration Time (Number #7)
Address: 0536H
0537H
Operational
Interface:
Panel / Software Communication
Related Section:
7.10
Default:
1200
Control
Mode:
PR
Unit:
ms
Range:
1 ~ 65500
Data Size:
16-bit
Format:
Decimal
Settings:
Please refer to P5-20 for the setting of acceleration/deceleration time in
PR mode.
P5-28 AC8 Acceleration/Deceleration Time (Number #8)
Address: 0538H
0539H
Operational
Interface:
Panel / Software Communication
Related Section:
7.10
Default:
1500
Control
Mode:
PR
Unit:
ms