EasyManua.ls Logo

Delta ASDA-A2 - CMAP E-CAM: AREA No.+The Point of DO on; ECRD E-CAM: Information of Disengaging Time

Delta ASDA-A2
721 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-207
P5-89 ECRD E-CAM: Information of Disengaging Time
Address: 05B2H
05B3H
Operational
Interface:
Panel / Software Communication
Related Section:
7.11
Default:
0
Control
Mode:
PR
Unit:
-
Range:
-1073741824 ~ +1073741823
Data Size:
32-bit
Format:
Decimal
Settings:
(Please refer to the definition of P5-88 U setting value 2)
NOTE
A2L does not support E-Cam function.
P5-90 CMAP
E-CAM: AREA No.+The Point of DO ON
Address: 05B4H
05B5H
Operational
Interface:
Panel / Software Communication
Related Section:
7.11
Default:
0
Control
Mode:
PR
Unit:
Degree (It was changed after firmware
V1.009)
Range:
0 ~ 360
Data Size:
16-bit
Format:
Decimal
Settings:
When E-cam is engaged, set the start angle of DO output (DO.
CAM_AREA).
NOTE
A2L does not support E-Cam function.

Table of Contents