EasyManuals Logo

Delta ASDA-A2 User Manual

Delta ASDA-A2
721 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #390 background imageLoading...
Page #390 background image
ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-139
P3-04 CWD Communication Timeout
Address: 0308H
0309H
Operational
Interface
Panel / Software Communication
Related Section:
9.2
Default
0
Control
Mode
ALL
Unit
sec
Range
0 ~ 20
Data Size
16-bit
Format
DEC
Settings
If the setting value is not 0, enable communication timeout
immediately. If it is set to 0, disable the function.
P3-05 CMM Communication Mechanism
Address: 030AH
030BH
Operational
Interface
Panel / Software Communication
Related Section:
9.2
Default
0
Control
Mode
ALL
Unit
-
Range
0x00 ~ 0x01
Data Size
16-bit
Format
Hexadecimal
Settings
Communication port can select one or more than one communications.
Communication Interface
0: RS232
1: RS485

Table of Contents

Other manuals for Delta ASDA-A2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 and is the answer not in the manual?

Delta ASDA-A2 Specifications

General IconGeneral
Control ModePosition, Speed, Torque
ModelASDA-A2 Series
Operating Voltage200 ~ 230VAC / 380 ~ 480VAC
Power Supply200-230VAC ±10%, single-phase
Communication InterfaceRS-485, CANopen
FeedbackIncremental encoder, Absolute encoder
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Operating Temperature0°C
Storage Temperature-20°C
Humidity20% to 90% RH (non-condensing)
Position Control Mode FeaturesElectronic Cam
WeightVaries depending on the model. Please refer to the specific model's datasheet.

Related product manuals