ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-181
P5-42 DLY2
Delay Time After Position Completed (Number
#2)
Address: 0554H
0555H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
200
Control
Mode
PR
Unit
ms
Range
0 ~ 32767
Data Size
16-bit
Format
Decimal
Settings
The 3
rd
Delay Time of PR mode
P5-43 DLY3
Delay Time After Position Completed (Number
#3)
Address: 0556H
0557H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
400
Control
Mode
PR
Unit
ms
Range
0 ~ 32767
Data Size
16-bit
Format
Decimal
Settings
The 4
th
Delay Time of PR mode
P5-44 DLY4
Delay Time After Position Completed (Number
#4)
Address: 0558H
0559H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
500
Control
Mode
PR
Unit
ms

Table of Contents

Other manuals for Delta ASDA-A2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 and is the answer not in the manual?

Delta ASDA-A2 Specifications

General IconGeneral
Control ModePosition, Speed, Torque
ModelASDA-A2 Series
Operating Voltage200 ~ 230VAC / 380 ~ 480VAC
Power Supply200-230VAC ±10%, single-phase
Communication InterfaceRS-485, CANopen
FeedbackIncremental encoder, Absolute encoder
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Operating Temperature0°C
Storage Temperature-20°C
Humidity20% to 90% RH (non-condensing)
Position Control Mode FeaturesElectronic Cam
WeightVaries depending on the model. Please refer to the specific model's datasheet.