ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-229
P6-06 PDEF3 PATH# 3 Definition
Address: 060CH
060DH
Operational
Interface:
Panel / Software Communication
Related Section:
7.10
Default:
0x00000000
Control
Mode:
PR
Unit:
-
Range:
0x00000000 ~ 0xFFFFFFFF
Data Size:
32-bit
Format:
Hexadecimal
Settings:
Please refer to the description of P6-02.
P6-07 PDAT3 PATH# 3 Data
Address: 060EH
060FH
Operational
Interface:
Panel / Software Communication
Related Section:
7.10
Default:
0
Control
Mode:
PR
Unit:
-
Range:
-2147483648 ~ +2147483647
Data Size:
32-bit
Format:
Decimal
Settings:
Please refer to the description of P6-03.
P6-08 PDEF4 PATH# 4 Definition
Address: 0610H
0611H
Operational
Interface:
Panel / Software Communication
Related Section:
7.10
Default:
0x00000000
Control
Mode:
PR
Unit:
-