ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-55
Data Size
16-bit
Format
Decimal
Settings
When capture synchronous axis is enabled, if desire to change the
synchronous error (P5-79), setting this parameter will do.
Write P1-16: P5-79 P5-79 + writing value
Read P1-16: Read value P5-79
NOTE
1 The setting value of this parameter is the accumulative value,
which will not be influenced by current error value.
2 The value of P5-79 can be monitored by monitoring variable 0x54.
P1-17 TEET
Compensation of Following ErrorAdditional
Time Setting
Address: 0122H
0123H
Operational
Interface
Panel / Software Communication
Related Section:
Default
0
Control
Mode
ALL
Unit
Ms; the smallest unit is usec
Range
-20.000 ~ +20.000 (three decimal point)
Data Size
16-bit
Format
Decimal
Example
1.5 = Motor speed x 1.5 ms (PUU)
Settings
When this function is enabled (P1-36 = 1), the system will make the
position error (PUU) close to 0 according to the compensation amount
of command. If the time delay is caused by other reasons, users could
setup the additional compensation time to compensate the position
error.
Additional compensation distance P1-17 x Motor speed
NOTE
1) Value of P1-36 has to set to 1.

Table of Contents

Other manuals for Delta ASDA-A2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 and is the answer not in the manual?

Delta ASDA-A2 Specifications

General IconGeneral
BrandDelta
ModelASDA-A2
CategoryController
LanguageEnglish

Related product manuals