ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-175
P5-31 AC11 Acceleration/Deceleration Time (Number #11)
Address: 053EH
053FH
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
3000
Control
Mode
PR
Unit
ms
Range
1 ~ 65500
Data Size
16-bit
Format
Decimal
Settings
Please refer to P5-20 for the setting of acceleration/deceleration time in
PR mode.
P5-32 AC12 Acceleration/Deceleration Time (Number #12)
Address: 0540H
0541H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
5000
Control
Mode
PR
Unit
ms
Range
1 ~ 65500
Data Size
16-bit
Format
Decimal
Settings
Please refer to P5-20 for the setting of acceleration/deceleration time in
PR mode.
P5-33 AC13 Acceleration/Deceleration Time (Number #13)
Address: 0542H
0543H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
8000
Control
Mode
PR
Unit
ms

Table of Contents

Other manuals for Delta ASDA-A2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 and is the answer not in the manual?

Delta ASDA-A2 Specifications

General IconGeneral
Control ModePosition, Speed, Torque
ModelASDA-A2 Series
Operating Voltage200 ~ 230VAC / 380 ~ 480VAC
Power Supply200-230VAC ±10%, single-phase
Communication InterfaceRS-485, CANopen
FeedbackIncremental encoder, Absolute encoder
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Operating Temperature0°C
Storage Temperature-20°C
Humidity20% to 90% RH (non-condensing)
Position Control Mode FeaturesElectronic Cam
WeightVaries depending on the model. Please refer to the specific model's datasheet.