EasyManua.ls Logo

Delta ASDA-A2

Delta ASDA-A2
721 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-175
P5-31 AC11 Acceleration/Deceleration Time (Number #11)
Address: 053EH
053FH
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
3000
Control
Mode
PR
Unit
ms
Range
1 ~ 65500
Data Size
16-bit
Format
Decimal
Settings
Please refer to P5-20 for the setting of acceleration/deceleration time in
PR mode.
P5-32 AC12 Acceleration/Deceleration Time (Number #12)
Address: 0540H
0541H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
5000
Control
Mode
PR
Unit
ms
Range
1 ~ 65500
Data Size
16-bit
Format
Decimal
Settings
Please refer to P5-20 for the setting of acceleration/deceleration time in
PR mode.
P5-33 AC13 Acceleration/Deceleration Time (Number #13)
Address: 0542H
0543H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
8000
Control
Mode
PR
Unit
ms

Table of Contents

Other manuals for Delta ASDA-A2

Related product manuals