ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-203
P5-85 ECME E-CAM: Number of Area
Address: 05AAH
05ABH
Operational
Interface
Panel / Software Communication
Related Section:
7.11
Default
0
Control
Mode
PR
Unit
-
Range 0 ~ (P5-821)
Data Size
16-bit
Format
Decimal
Settings
The area number of E-cam when E-cam engaged.
NOTE
A2L does not support E-Cam function.
P5-86
ECAX E-CAM: Master Axis Position
Address: 05ACH
05ADH
Operational
Interface
Panel / Software Communication
Related Section:
7.11
Default
0
Control
Mode
PR
Unit
-
Range
-2147483648 ~ +2147483647
Data Size
32-bit
Format
Decimal
Settings
The position counter of the E-Cam Master
NOTE
1. This parameter can be wrote when E-Cam stops (Please refer
toP5-88, X=0).
2. A2L does not support E-Cam function.

Table of Contents

Other manuals for Delta ASDA-A2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 and is the answer not in the manual?

Delta ASDA-A2 Specifications

General IconGeneral
Control ModePosition, Speed, Torque
ModelASDA-A2 Series
Operating Voltage200 ~ 230VAC / 380 ~ 480VAC
Power Supply200-230VAC ±10%, single-phase
Communication InterfaceRS-485, CANopen
FeedbackIncremental encoder, Absolute encoder
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Operating Temperature0°C
Storage Temperature-20°C
Humidity20% to 90% RH (non-condensing)
Position Control Mode FeaturesElectronic Cam
WeightVaries depending on the model. Please refer to the specific model's datasheet.

Related product manuals