ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-109
Settings:
Semi-auto setting
Reserved
Not in use
Semi-auto Setting:
1: It means the inertia estimation in semi-auto mode is completed.
The inertia value can be accessed via P1-37.
0: 1. When the display is 0, it means the inertia adjustment is not
completed and is adjusting.
2. When the setting is 0, it means the inertia adjustment is not
completed and is adjusting.
P2-34 SDEV The Condition of Overspeed Warning
Address: 0244H
0245H
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
5000
Control
Mode:
S
Unit:
r/min
Range:
1 ~ 5000
Data Size:
16-bit
Format:
Decimal
Settings:
The setting of over speed warning in servo drive error display (P0-01)
P2-35 PDEV
Condition of Excessive Position Control
Deviation Warning
Address: 0246H
0247H
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
3840000
Control
Mode:
PT/PR
Unit:
pulse
Range:
1 ~ 128000000
Data Size:
32-bit
Format:
Decimal