ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-109
Settings
Semi-auto setting
Reserved
Not in use
Semi-auto Setting:
1: It means the inertia estimation in semi-auto mode is completed.
The inertia value can be accessed via P1-37.
0: 1. When the display is 0, it means the inertia adjustment is not
completed and is adjusting.
2. When the setting is 0, it means the inertia adjustment is not
completed and is adjusting.
P2-34 SDEV The Condition of Overspeed Warning
Address: 0244H
0245H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
5000
Control
Mode
S
Unit
r/min
Range
1 ~ 5000
Data Size
16-bit
Format
Decimal
Settings
The setting of over speed warning in servo drive error display (P0-01)
P2-35 PDEV
Condition of Excessive Position Control
Deviation Warning
Address: 0246H
0247H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
3840000
Control
Mode
PTPR
Unit
pulse
Range
1 ~ 128000000
Data Size
32-bit
Format
Decimal

Table of Contents

Other manuals for Delta ASDA-A2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 and is the answer not in the manual?

Delta ASDA-A2 Specifications

General IconGeneral
BrandDelta
ModelASDA-A2
CategoryController
LanguageEnglish

Related product manuals