ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-95
P2-08■
PCTL Special Parameter Write-in
Address: 0210H
0211H
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
0
Control
Mode:
ALL
Unit:
-
Range:
0 ~ 65535
Data Size:
16-bit
Format:
Decimal
Settings:
Special parameter write-in:
Parameter
code
Function
10 Reset the parameter (Apply to the power again after reset)
20 P4-10 is writable
22 P4-11~P4-21are writable
30,35 Save the data of COMPARE, CAPTURE, E-Cam
406
Enable forced DO mode
400
When forced DO mode is enabled, it can switch back to
the normal DO mode.
NOTE
A2L does not support E-Cam function.
P2-09 DRT DI Debouncing Time
Address: 0212H
0213H
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
2
Control
Mode:
ALL
Unit:
ms
Range:
0 ~ 20
Data Size:
16-bit
Format:
Decimal
Settings:
When the environmental noise is big, increasing the setting value can
enhance the control stability. However, if the value is set too big, the
response time will be influenced.