ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-95
P2-08
PCTL Special Parameter Write-in
Address: 0210H
0211H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
0
Control
Mode
ALL
Unit
-
Range
0 ~ 65535
Data Size
16-bit
Format
Decimal
Settings
Special parameter write-in:
Parameter
code
Function
10 Reset the parameter (Apply to the power again after reset)
20 P4-10 is writable
22 P4-11~P4-21are writable
30,35 Save the data of COMPARE, CAPTURE, E-Cam
406
Enable forced DO mode
400
When forced DO mode is enabled, it can switch back to
the normal DO mode.
NOTE
A2L does not support E-Cam function.
P2-09 DRT DI Debouncing Time
Address: 0212H
0213H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
2
Control
Mode
ALL
Unit
ms
Range
0 ~ 20
Data Size
16-bit
Format
Decimal
Settings
When the environmental noise is big, increasing the setting value can
enhance the control stability. However, if the value is set too big, the
response time will be influenced.

Table of Contents

Other manuals for Delta ASDA-A2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 and is the answer not in the manual?

Delta ASDA-A2 Specifications

General IconGeneral
BrandDelta
ModelASDA-A2
CategoryController
LanguageEnglish

Related product manuals