ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-199
P5-78 CSDS
The Interval Pulse Number between Each
Synchronous Capture Axis
Address: 059CH
059DH
Operational
Interface
Panel / Software Communication
Related Section: -
Default
100
Control
Mode
ALL
Unit
Pulse
Range
10 ~ +100000000
Data Size
32-bit
Format
Decimal
Settings
It is the moving distance of synchronous capture axis between two
CAP actions.
The new value can be written into the parameter not until CAP is
disabled (P5-39, X0=0).
P5-79
CSDS
Error Pulse Number of Synchronous Capture
Axis
Address: 059EH
059FH
Operational
Interface
Panel / Software Communication
Related Section: -
Default
0
Control
Mode
ALL
Unit
Pulse unit of capture axis
Range
-2147483648 ~ +2147483647
Data Size
32-bit
Format
Decimal

Table of Contents

Other manuals for Delta ASDA-A2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 and is the answer not in the manual?

Delta ASDA-A2 Specifications

General IconGeneral
Control ModePosition, Speed, Torque
ModelASDA-A2 Series
Operating Voltage200 ~ 230VAC / 380 ~ 480VAC
Power Supply200-230VAC ±10%, single-phase
Communication InterfaceRS-485, CANopen
FeedbackIncremental encoder, Absolute encoder
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Operating Temperature0°C
Storage Temperature-20°C
Humidity20% to 90% RH (non-condensing)
Position Control Mode FeaturesElectronic Cam
WeightVaries depending on the model. Please refer to the specific model's datasheet.

Related product manuals