Chapter 8 Parameters ASDA-A2
8-182 Revision February, 2017
Range:
0 ~ 32767
Data Size:
16-bit
Format:
Decimal
Settings:
The 5
th
Delay Time of PR mode
P5-45 DLY5
Delay Time After Position Completed (Number
#5)
Address: 055AH
055BH
Operational
Interface:
Panel / Software Communication
Related Section:
7.10
Default:
800
Control
Mode:
PR
Unit:
ms
Range:
0 ~ 32767
Data Size:
16-bit
Format:
Decimal
Settings:
The 6
th
Delay Time of PR mode
P5-46 DLY6
Delay Time After Position Completed (Number
#6)
Address: 055CH
055DH
Operational
Interface:
Panel / Software Communication
Related Section:
7.10
Default:
1000
Control
Mode:
PR
Unit:
ms
Range:
0 ~ 32767
Data Size:
16-bit
Format:
Decimal
Settings:
The 7
th
Delay Time of PR mode