ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-23
P0-17 CM1A Status Monitor Register 1 Selection
Address: 0022H
0023H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
0
Control
Mode
-
Unit
-
Range
0 ~ 127
Data Size
16-bit
Format
Decimal
Settings
Please refer to Chapter 7.2.1, Description of Monitoring Variable for the
setting value.
For example, if P0-17 is set to 07, then reading P0-09 means reading
Motor speed (r/min) .
P0-18 CM2A Status Monitor Register 2 Selection
Address: 0024H
0025H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
0
Control
Mode
-
Unit
-
Range
0 ~ 127
Data Size
16-bit
Format
Decimal
Settings
Please refer to Chapter 7.2.1, Description of Monitoring Variable for the
setting value.