Chapter 8 Parameters ASDA-A2
8-148 Revision February, 2017
P4-02
ASH3 Fault Record (N-2)
Address: 0404H
0405H
Operational
Interface
Panel / Software Communication
Related Section:
4.4.1
Default
0
Control
Mode
ALL
Unit
-
Range
-
Data Size
32-bit
Format
Hexadecimal
Settings
The last third abnormal status record
Low word: LXXXX: display ALM number
High word: hYYYY: display the error code corresponds to CANopen /
DMCNET
P4-03
ASH4 Fault Record (N-3)
Address: 0406H
0407H
Operational
Interface
Panel / Software Communication
Related Section:
4.4.1
Default
0
Control
Mode
ALL
Unit
-
Range
-
Data Size
32-bit
Format
Hexadecimal
Settings
The last fourth abnormal status record
Low word: LXXXX: display ALM number
High word: hYYYY: display the error code corresponds to CANopen /
DMCNET

Table of Contents

Other manuals for Delta ASDA-A2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 and is the answer not in the manual?

Delta ASDA-A2 Specifications

General IconGeneral
Control ModePosition, Speed, Torque
ModelASDA-A2 Series
Operating Voltage200 ~ 230VAC / 380 ~ 480VAC
Power Supply200-230VAC ±10%, single-phase
Communication InterfaceRS-485, CANopen
FeedbackIncremental encoder, Absolute encoder
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Operating Temperature0°C
Storage Temperature-20°C
Humidity20% to 90% RH (non-condensing)
Position Control Mode FeaturesElectronic Cam
WeightVaries depending on the model. Please refer to the specific model's datasheet.