Chapter 8 Parameters ASDA-A2
8-92 Revision February, 2017
P2-02 PFG Position Feed Forward Gain
Address: 0204H
0205H
Operational
Interface
Panel / Software Communication
Related Section:
6.2.8
Default
50
Control
Mode
PTPR
Unit
%
Range
0 ~ 100
Data Size
16-bit
Format
Decimal
Settings
If the position command is changed smoothly, increasing the gain
value can reduce the position error.
If the position command is not changed smoothly, decreasing the gain
value can tackle the problem of mechanical vibration.
P2-03 PFF
Smooth Constant of Position Feed Forward
Gain
Address: 0206H
0207H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
5
Control
Mode
PTPR
Unit
ms
Range
2 ~ 100
Data Size
16-bit
Format
Decimal
Settings
If the position command is changed smoothly, decreasing the value
can reduce the position error. If the position command is not changed
smoothly, increasing the value can tackle the problem of mechanical
vibration.

Table of Contents

Other manuals for Delta ASDA-A2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 and is the answer not in the manual?

Delta ASDA-A2 Specifications

General IconGeneral
Control ModePosition, Speed, Torque
ModelASDA-A2 Series
Operating Voltage200 ~ 230VAC / 380 ~ 480VAC
Power Supply200-230VAC ±10%, single-phase
Communication InterfaceRS-485, CANopen
FeedbackIncremental encoder, Absolute encoder
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Operating Temperature0°C
Storage Temperature-20°C
Humidity20% to 90% RH (non-condensing)
Position Control Mode FeaturesElectronic Cam
WeightVaries depending on the model. Please refer to the specific model's datasheet.

Related product manuals