Chapter 8 Parameters ASDA-A2
8-192 Revision February, 2017
P5-64 POV4 Target Speed Setting #4
Address: 0580H
0581H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
300.0 3000
Control
Mode
PR
Unit
1 r/min 0.1 r/min
Range
0.1 ~ 6000.0 1 ~ 60000
Data Size
16-bit
Format
Decimal
Example
1= 1 r/min 10 = 1r/min
Settings
The 5
th
target speed of PR mode
P5-65 POV5 Target Speed Setting #5
Address: 0582H
0583H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
500.0 5000
Control
Mode
PR
Unit
1 r/min 0.1 r/min
Range
0.1 ~ 6000.0 1 ~ 60000
Data Size
16-bit
Format
Decimal
Example
1= 1 r/min 10 = 1r/min
Settings
The 6
th
target speed of PR mode