EasyManuals Logo

Delta ASDA-A2 User Manual

Delta ASDA-A2
721 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #290 background imageLoading...
Page #290 background image
ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-39
Format
Decimal
Settings The value of parameter P0-09 will change within the range between P0-
54 and P0-55 and then output after the filtering time determined by
parameter P0-53.
P0-56 ~
P0-62
Reserved
P0-63 VGT The Time when Voltage Exceeding 400V
Address: 007EH
007FH
Operational
Interface
Panel / Software Communication
Related Section: N/A
Default
0x0
Control
Mode
ALL
Unit
ms
Range
0x00000000 ~ 0x7FFFFFFF
Data Size
32-bit
Format
Decimal
Settings
Record the accumulative time when the drive’s voltage exceeding
400V.

Table of Contents

Other manuals for Delta ASDA-A2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 and is the answer not in the manual?

Delta ASDA-A2 Specifications

General IconGeneral
Control ModePosition, Speed, Torque
ModelASDA-A2 Series
Operating Voltage200 ~ 230VAC / 380 ~ 480VAC
Power Supply200-230VAC ±10%, single-phase
Communication InterfaceRS-485, CANopen
FeedbackIncremental encoder, Absolute encoder
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Operating Temperature0°C
Storage Temperature-20°C
Humidity20% to 90% RH (non-condensing)
Position Control Mode FeaturesElectronic Cam
WeightVaries depending on the model. Please refer to the specific model's datasheet.

Related product manuals