501-11-13 Glass, Frames and Mechanisms 501-11-13
REMOVAL AND INSTALLATION
Opera Window Glass
General Equipment
Hot air gun
Direct glazing cutter for bonded glass
Mixer/Application gun
Removal
1. NOTE: Should the ambient temperature fall
below 10°C heat the cartridges for
approximately 15 minutes by placing them on
a warm radiator, or by using a hot air gun set
at approximately 25°C.
Heat the polyurethane (PU) adhesive if
necessary.
All vehicles
CAUTION: When removing fasteners,
take extreme care, as they may be
easily broken.
1. Rem the C pillar trim cover. ove