303-06-204 Starting System 303-06-204
DIAGNOSIS AND TESTING (CONTINUED)
E1017 EN 09/2001 2002 Bantam
CONDITIONS
DETAILS/RESULTS/ACTIONS
2 Measure the voltage between the starter motor
terminal B, circuit 30 (RD) and ground.
• Is the voltage greater than 10 volts?
Yes
GO TO A5
No
REPAIR circuit 30 (RD). TEST the system
for normal operation.
A5: CHECK THE STARTER GROUND CIRCUIT
1 Measure the resistance between the starter
motor casing and negative (-) battery terminal.
• Is the resistance less than 5 ohms?
Yes
INSTALL a new starter motor. TEST the
system for normal operation.
No
CLEAN and REPAIR grounds as required.
TEST the system for normal operation.
A6: CHECK B+ TO STARTER RELAY
1.
Starter relay
2 Measure the voltage between the starter relay
connector pin 5, circuit 30 (RD) and ground.
• Is the voltage greater than 10 volts?
Yes
GO TO A7
No
REPAIR circuit 30 (RD). TEST the system
for normal operation.