303-06-205 Starting System 303-06-205
DIAGNOSIS AND TESTING (CONTINUED)
E1017 EN 09/2001 2002 Bantam
CONDITIONS
DETAILS/RESULTS/ACTIONS
A7: CHECK RELAY GROUND CIRCUIT
1 Measure the resistance between the starter
relay connector pin 1, circuit 31 (BK) and
ground.
• Is the resistance less than 5 ohms?
Yes
GO TO A8
No
REPAIR circuit 31 (BK). TEST the system
for normal operation.
A8: CHECK RELAY SWITCHING CIRCUIT
1.
2 Measure the voltage between the starter relay
connector pin 2, circuit 50 (GY) and ground.
• Is the voltage greater than 10 volts?
Yes
GO TO A13
No
GO TO A9
A9: CHECK FUSE 40 (60A)
1.
Fuse 40 (60A)
• Is the fuse OK?
Yes
GO TO A10
No
INSTALL a new fuse 40 (60A). TEST the
system for normal operation. If fuse fails
again GO TO A15