114 Upgrade and Maintenance Manual RX2540 M2
Basic software procedures
Ê Ensure that all pre-fail / fail status issues have been resolved in ServerView
Operations Manager.
5.2.8 Enabling SVOM boot watchdog functionality
If ServerView Operations Manager boot watchdog functionality has been
disabled for firmware upgrade purposes (see section 5.1.2 on page 96), it has
to be re-enabled to complete the maintenance task.
Timer settings can be configured in the BIOS or using the ServerView iRMC
web frontend:
Configuring boot watchdog settings in the BIOS
Ê Enter the BIOS.
Ê Select the Server Mgmt menu.
Ê Under Boot Watchdog set the Action setting to Reset.
Ê Save your changes and exit the BIOS.
I For detailed information on how to access the BIOS and modify settings,
refer to the corresponding BIOS Setup Utility reference manual.
Configuring boot watchdog settings using the iRMC web frontend
Ê Enter the ServerView iRMC web frontend.
Ê Select the Server Management menu.
Ê Under Watchdog Settings ensure that the check box next to Boot Watchdog is
selected. From the drop down list choose Reset and specify the desired
timeout delay.
Ê Click Apply for the changes to take effect.
I For detailed information on iRMC settings, refer to the "Integrated
Remote Management Controller" user guide.