RX2540 M2 Upgrade and Maintenance Manual 197
Hard disk drives (HDD) and solid state drives (SSD)
7.4.3 Removing 2.5-inch HDD/SSD modules
7.4.3.1 Preliminary steps
Ê If the HDD module to be removed is combined into a RAID array, please
proceed as follows:
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager or BIOS Utility.
V CAUTION!
All data on all HDDs/SSDs in the array will be lost when deleting the
array. Be sure to back up your data before deleting a RAID array.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools: tool-less
RAID level Procedure
RAID 0
Only remove an HDD module combined in a RAID 0
array if defective.
V CAUTION!
Removing an operational HDD module will
result in data loss!
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID 5
array will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I After replacing the HDD module, RAID rebuild
will be performed as a background process as
described in section "Performing a RAID array
rebuild" on page 121.

Table of Contents

Related product manuals