RX2540 M2 Upgrade and Maintenance Manual 339
Expansion cards and backup units
8.8.3.4 Concluding steps
Ê If a riser module 1 is installed, remove the riser module 1 refer to"Installing
the riser module 1 (HL)" on page 85 .
Ê "Reassembling" on page 73
Ê "Connecting the power cord" on page 79
Ê "Switching on the server" on page 82
Ê "Enabling SVOM boot watchdog functionality" on page 114
8.8.4 Replacing the DynamicLoM module
I WWN and MAC addresses will be changed by replacing a DynamicLoM
module with different module types or by replacing the system board.
Inform the customer about that before starting these tasks.After doing
these tasks, inform the customer about the changed WWN and MAC
addresses.
8.8.4.1 Preliminary steps
Ê "Disabling SVOM boot watchdog functionality" on page 96
Ê "Shutting down the server" on page 65
Ê "Disconnecting the power cord" on page 66
Ê "Getting access to the component" on page 68
Ê If a riser module 1 is installed, remove the riser module 1 refer to "Removing
the riser module 1 (HL)" on page 84.
Upgrade and Repair Unit
(URU)
Hardware: 10 minutes
Tool: – Phillips PH1 / (+) No. 1 screw driver