310 Upgrade and Maintenance Manual RX2540 M2
Expansion cards and backup units
8.6.5.2 Removing the defective GPGPU card
Ê If applicable, remove the riser module 1 as described in section "Removing
the riser module 1" on page 297.
Ê If applicable, remove the riser module 2 as described in section "Removing
the riser module 2" on page 307.
Ê Remove the GPGPU card as described in section "Removing a GPGPU
card (FL)" on page 298.
8.6.5.3 Installing the new GPGPU card
Ê Install the new GPGPU card as described in section "Installing a GPGPU
card in a riser module" on page 286.
Ê If applicable, install the riser module 1 as described in section "Installing the
riser module 1" on page 289.
Ê If applicable, install the riser module 2 as described in section "Installing the
riser module 2 (FL)" on page 301.
8.6.5.4 Connecting cables to the GPGPU card
Ê If applicable, connect power cables to the GPGPU card.
I For a complete cabling overview, please refer to section "List of used
cables" on page 559.
8.6.5.5 Connecting a battery backup unit to the expansion card
Ê If applicable, connect an FBU to the GPGPU card riser module 1 as
described in section "Installing the FBU on the riser card holder" on
page 291.
Ê If applicable, connect an FBU to the GPGPU card riser module 2 as
described in section "Installing the FBU riser module 2" on page 302.
8.6.5.6 Concluding steps
Ê "Reassembling" on page 73
Ê "Connecting the power cord" on page 79
Ê "Switching on the server" on page 82