374 Upgrade and Maintenance Manual RX2540 M2
10.3 Removing CPUs
10.3.1 Preliminary steps
Ê "Suspending BitLocker functionality" on page 95
Ê "Disabling SVOM boot watchdog functionality" on page 96
Ê "Shutting down the server" on page 65
Ê "Disconnecting the power cord" on page 66
Ê "Getting access to the component" on page 68
10.3.2 Removing a CPU
I This description applies to the following procedures:
– Removing CPU 2 from a 2 CPU configuration
– Removing CPUs from a defective system board
Ê Remove the desired CPU heat sink as described in section "Removing CPU
heat sinks" on page 387.
Upgrade and Repair Unit
(URU)
Hardware: 15 minutes
Software: 5 minutes
Tool: Phillips PH2 / (+) No. 2 screw driver