RX2540 M2 Upgrade and Maintenance Manual 601
The minimum startup configuration consists of the following components and
cables:
Ê "Shutting down the server" on page 65
Ê "Disconnecting the power cord" on page 66
Ê Take the system down to its minimum startup configuration.
Ê "Connecting the power cord" on page 79
Ê Connect a keyboard, mouse and display to the server.
Ê "Switching on the server" on page 82
V CAUTION!
Since the fan module is not included in the minimum startup
configuration, the server must be shut down immediately after the
diagnostic process is complete (POST phase has been passed).
The minimum startup configuration must be used exclusively for
diagnostic purposes by maintenance personnel, never in daily
operation!
Component Notes
System board no TPM, UFM or expansion cards installed
1 CPU with CPU heat sink installed in CPU slot CPU 1
1 memory module installed in DIMM slot 1A
Front panel module
1 PSU installed in PSU bay PSU 1
Table 9: Minimum startup configuration - components
Cable Notes
Front panel cable
Power cable
Table 10: Minimum startup configuration - cables