Torque control under Real sensorless vector control and vector control
PARAMETERS
221
5
Forward/reverse rotation speed limit using analog input (Pr.1113="9999",
Pr.807="2")
When performing speed limit by analog inputs to terminal 1, speed limit can be switched between forward and reverse
rotation by its voltage polarity.
When Pr.868 Terminal 1 function assignment ="5", forward/reverse speed limit is enabled.
If 0 to 10 V is input, forward rotation speed limit is applied. Reverse rotation speed limit at this time is the value of Pr.1
Maximum frequency.
If -10 to 0 V is input, reverse rotation speed limit is applied. Forward rotation speed limit at this time is the value of Pr.1.
Upper speed limit is the value of Pr.1 for both forward and reverse rotations.
NOTE
To perform speed limit by using the terminal 1, calibrate the terminal 1. (Refer to page 415.)
Pr.7
ONOFF
Start signal
Speed
Time
Speed
Forward rotation
Reverse rotation
Output
torque (%)
0
Speed
Reverse rotation
Forward rotation
Output torque (%)
Terminal 1 input
Pr.1
0
Torque controllable range
Torque controllable range
Torque controllable range
Terminal 1
input
Terminal 1 input
(-10 to 0V)
The reverse
rotation speed
limit
150 150
150 150
Pr.1
Pr.8
Pr.1
Pr.7
ONOFF
Start signal
Speed
Time
Terminal 1 input (0 to 10V)
The forward rotation speed
limit
Pr.8
Pr.1
Torque controllable range
When terminal 1 input is "-10 to 0V" When terminal 1 input is "0 to 10V"
The reverse rotation
speed limit
The forward rotation
speed limit

Table of Contents