Parameter clear / all parameter clear
PARAMETERS
631
5
5.17 Parameter clear / all parameter clear
POINTPOINT
• Set "1" to Pr.CLR Parameter clear, ALL.CL All parameter clear to initialize all parameters. (Parameters cannot be cleared
when Pr.77 Parameter write selection = "1".)
• Pr.CL does not clear calibration parameters or the terminal function selection parameters.
• Refer to the parameter list on page 711 for parameters cleared with this operation.
NOTE
• and are displayed alternately... Why?
- The inverter is not in the PU operation mode.
1) Press .
is lit, and " " appears on the monitor. (When Pr.79 ="0" (initial value))
2)Press to clear the parameter.
• Stop the inverter first. A writing error occurs if a parameter clear is attempted while the inverter is running.
To perform a parameter clear, the inverter must be in the PU operation mode even if "2" is set to Pr.77.
• For availability of parameter clear and all parameter clear for each parameter, refer to the parameter list on page 711.
Operation
1.
Screen at power-ON
The monitor display appears.
2.
Changing the operation mode
Press to choose the PU operation mode. [PU] indicator is lit.
3.
Parameter setting mode
Press to choose the parameter setting mode. (The parameter number read previously appears.)
4.
Selecting the parameter number
To perform a parameter clear, turn to , and to perform all parameter clear, turn it to and press
. " " (initial value) appears.
5.
Parameter clear
Turn to change the set value to " ". Press to enter the setting. " " and " " ( ) flicker
alternately after parameters are cleared.
Turn to read another parameter.
Press to show the setting again.
Press twice to show the next parameter.
Setting
Description
Pr.CLR Parameter clear ALL.CL All parameter clear
0 Initial display (Parameters are not cleared.)
1
Returns parameters excluding calibration
parameters and terminal function selection
parameters to their initial values.
Returns all parameters which can be cleared
including calibration parameters and terminal
function selection parameters to their initial values.