(M) Monitor display and monitor output signal
380
PARAMETERS
Energy saving monitor list
• The items that can be monitored on the power saving monitor (Pr.52, Pr.54, Pr.158, Pr.774 to Pr.776, Pr.992 = "50") are
indicated below.
(Only [1 Power saving] and [3 Average power saving] can be set to
Pr.54
(terminal FM, terminal CA)
and Pr.158
(terminal AM).)
• The items that can be monitored on the cumulative energy saving monitor (Pr.52, Pr.774 to Pr.776, Pr.992 = "51") are
indicated below.
(The monitor value of the cumulative monitor can be shifted to the right with Pr.891 Cumulative power monitor digit
shifted times.)
Energy saving
monitored item
Description and formula Increment
Parameter setting
Pr.895 Pr.896 Pr.897 Pr.899
1 Power saving
The difference between the estimated value of the
required power during commercial power supply
operation and the input power calculated with the inverter.
Power supply during commercial power supply
operation - input power monitor
0.01 kW/
0.1 kW
9999
9999
2 Power saving rate
The power saving ratio with the commercial power
supply operation as 100%.
100
0.1%
0
The power saving ratio with Pr.893 as 100%.
100
1
3
Average power
saving
The average power saving per hour during a
predetermined time (Pr.897).
0.01 kWh/
0.1 kWh
9999
9999
0 to
1000 h
4
Average power
saving rate
The average power saving ratio with the
commercial power supply operation as 100%.
100
0.1%
0
The average power saving ratio with Pr.893 as 100%.
100
1
5
Average power cost
savings
The average power saving in terms of cost.
[3 Average power saving] Pr.896
0.01/0.1
-
0 to
500
Energy saving
monitored item
Description and formula Increment
Parameter setting
Pr.895 Pr.896 Pr.897 Pr.899
6
Power saving
amount
The cumulative power saving is added up per hour.
([1 Power saving] t)
0.01 kWh/
0.1 kWh
9999
9999
7 Power cost saving
The power saving amount in terms of cost.
[6 Power saving amount] Pr.896
0.01/0.1
0 to
500
8
Annual power
saving amount
Estimated value of annual power saving amount.
24 365
0.01 kWh/
0.1 kWh
9999
0 to
100%
9
Annual power cost
savings
Annual power saving amount in terms of cost.
[8 Annual power saving amount] Pr.896
0.01/0.1
0 to
500
For communication, (RS-485 communication, communication option), the display increments are 1. For example, "10.00 kWh" is displayed as
"10" for communication data.
When using the LCD operation panel or the parameter unit, "kW" is displayed
The increment differs according to capacities. (FR-A820-03160(55K) or lower, FR-A840-01800(55K) or lower / FR-A820-03800(75K) or
higher, FR-A840-02160(75K) or higher.)
[1 Power saving]
Power during commercial power supply operation
([1 Power saving] t)
Pr.897
([2 Power saving rate] t)
Pr.897
Pr.893
[3 Average power saving]
[6 Power saving amount]
Operation time during power saving accumulation