(N) Operation via communication and its settings
576
PARAMETERS
NOTE
• Set 65520 (HFFF0) as a parameter value "8888" and 65535 (HFFFF) as "9999".
• For the instruction codes HFF, HEC and HF3, their values are held once written but cleared to zero when an inverter reset or
all clear is performed.
• When a 32-bit parameter setting or monitored value is read and the read value exceeds HFFFF, the reply data will be HFFFF.
Example) When reading the C3 (Pr.902) and C6 (Pr.904) settings from the inverter of station No. 0.
To read/write C3 (Pr.902) or C6 (Pr.904) after inverter reset or parameter clear, execute from (a) again.
List of calibration parameters
Computer send data Inverter send data Description
a ENQ 00 FF 0 01 7D ACK 00 Set "H01" in the extended link parameter
b ENQ 00 EC 0 01 79 ACK 00 Set "H01" in second parameter changing
c ENQ 00 5E 0 0A STX 00 0000 ETX 20 C3 (Pr.902) is read. 0% is read.
d ENQ 00 60 0 F6 STX 00 0000 ETX 20 C6 (Pr.904) is read. 0% is read.
Pr. Name
Instruction
code
Read
Write
Extended
C2 (902)
Terminal 2 frequency setting
bias frequency
5E DE 1
C3 (902)
Terminal 2 frequency setting
bias
5E DE 1
125 (903)
Terminal 2 frequency setting
gain frequency
5F DF 1
C4 (903)
Terminal 2 frequency setting
gain
5F DF 1
C5 (904)
Terminal 4 frequency setting
bias frequency
60 E0 1
C6 (904)
Terminal 4 frequency setting
bias
60 E0 1
126 (905)
Terminal 4 frequency setting
gain frequency
61 E1 1
C7 (905)
Terminal 4 frequency setting
gain
61 E1 1
C12 (917)
Terminal 1 bias frequency
(speed)
11 91 9
C13 (917) Terminal 1 bias (speed) 11 91 9
C14 (918)
Terminal 1 gain frequency
(speed)
12 92 9
C15 (918) Terminal 1 gain (speed) 12 92 9
C16 (919)
Terminal 1 bias command
(torque)
13 93 9
C17 (919) Terminal 1 bias (torque) 13 93 9
C18 (920)
Terminal 1 gain command
(torque)
14 94 9
C19 (920) Terminal 1 gain (torque) 14 94 9
C8 (930) Current output bias signal 1E 9E 9
C9 (930) Current output bias current 1E 9E 9
C10 (931) Current output gain signal 1F 9F 9
C11 (931) Current output gain current 1F 9F 9
C38 (932)
Terminal 4 bias command
(torque)
20 A0 9
C39 (932) Terminal 4 bias (torque) 20 A0 9
C40 (933)
Terminal 4 gain command
(torque)
21 A1 9
C41 (933) Terminal 4 gain (torque) 21 A1 9
C42 (934) PID display bias coefficient 22 A2 9
C43 (934) PID display bias analog value 22 A2 9
C44 (935) PID display gain coefficient 23 A3 9
C45 (935) PID display gain analog value 23 A3 9
Pr. Name
Instruction
code
Read
Write
Extended