(E) Environment setting parameters
272
PARAMETERS
Automatic parameter setting (Pr.999)
• Select which parameters to automatically set from the table below, and set them in Pr.999. Multiple parameter settings are
changed automatically. Refer to page 273 for the list of parameters that are changed automatically.
NOTE
• If the automatic setting is performed with Pr.999 or the automatic parameter setting mode, the settings including the changed
parameter settings (changed from the initial setting) will be automatically changed. Before performing the automatic setting,
confirm that changing the parameters will not cause any problem.
PID monitor indicator setting (Pr.999 = "1 or 2")
Enabled when the FR-PU07-01 is used.
Pr.999
Setting
Description
Operation in the automatic parameter setting
mode
1 Sets the standard monitor indicator setting of PID control.
(AUTO) (PID) Write "1"
2 Automatically sets the monitor indicator for PID control.
(AUTO) (PID) Write "2"
10
Automatically sets the communication parameters for the GOT
connection with a PU connector ("Controller Type" in GOT:
FREQROL 500/700/800, SENSORLESS SERVO)
(AUTO) (GOT) Write "1"
11
Automatically sets the communication parameters for the GOT
connection with RS-485 terminals ("Controller Type" in GOT:
FREQROL 500/700/800, SENSORLESS SERVO)
—
12
Automatically sets the communication parameters for the GOT
connection with a PU connector ("Controller Type" in GOT:
FREQROL 800(Automatic Negotiation))
(AUTO) (GOT) Write "2"
13
Automatically sets the communication parameters for the GOT
connection with RS-485 terminals ("Controller Type" in GOT:
FREQROL 800(Automatic Negotiation))
—
20 50 Hz rated frequency
Sets the related parameters of the rated
frequency according to the power supply
frequency
(AUTO) (F50) Write "1"
21 60 Hz rated frequency —
Pr. Name Initial value Pr.999="1" Pr.999="2" Refer to page
759 PID unit selection
9999 9999 4
514
1142 Second PID unit selection
9999 9999 4
774 Operation panel monitor selection 1
9999 9999 52
359
775 Operation panel monitor selection 2
9999 9999 53
776 Operation panel monitor selection 3
9999 9999 54
C42 (934) PID display bias coefficient
9999 9999 0
514
C44 (935) PID display gain coefficient
9999 9999 100
1136 Second PID display bias coefficient
9999 9999 0
1138 Second PID display gain coefficient
9999 9999 100
— 3-step monitor setting
— Disabled Enabled —
— Extended direct setting
— Disabled Enabled —
— Dedicated parameter list function
— Disabled Enabled —