(A) Application parameters
474
PARAMETERS
 The speed deviation excess detection frequency when FR-A8AP (option) is mounted during vector control. (For the details, refer to page 206.)
Connection diagram
NOTE
The automatic restart after instantaneous power failure function and orientation function do not operate when brake
sequence is selected.
To use this function, set the acceleration/deceleration time to 1 s or higher.
Changing the terminal assignment using Pr.178 to Pr.189 (input terminal function selection) and Pr.190 to Pr.196 (output
terminal function selection) may affect the other functions. Set parameters after confirming the function of each terminal.
642
A120
Second brake opening
frequency
3 Hz 0 to 30 Hz Refer to Pr.278.
Set the second brake sequence
function.
The second brake sequence function
is enabled when the RT signal is ON.
643
A121
Second brake opening
current
130% 0 to 400% Refer to Pr.279.
644
A122
Second brake opening
current detection time
0.3 s 0 to 2 s Refer to Pr.280.
645
A123
Second brake operation
time at start
0.3 s 0 to 5 s Refer to Pr.281.
646
A124
Second brake operation
frequency
6 Hz 0 to 30 Hz Refer to Pr.282.
647
A125
Second brake operation
time at stop
0.3 s 0 to 5 s Refer to Pr.283.
648
A126
Second deceleration
detection function selection
0 0, 1 Refer to Pr.284.
650
A128
Second brake opening
current selection
0 0, 1 Refer to Pr.639.
651
A129
Second brake operation
frequency selection
0 0, 1 Refer to Pr.640.
Pr. Name
Initial
value
Setting
range
Description
Mechanical
brake
R/L1
S/L2
T/L3
Motor
MC
STF
RH
AU(BRI)
1
SD
MC
24VDC
Brake opening request
signal (BOF)
Start signal
Multi-speed signal
Brake opening completion signal
(BRI)
Sink logic
Pr.184 = 15
Pr.190 = 20
Power
supply
U
V
W
RUN(BOF)
SE
∗2
∗3
MCCB
 The input signal terminals differ by the settings
of Pr.178 to Pr.189.
 The output signal terminals differ by the settings
of Pr.190 to Pr.196.
 Be careful of the permissible current of the built-in
transistors on the inverter. (24 VDC 0.1 A)